What It Means
- CBK45UHPT, CBK45UHVT: R-input not available
- Open Circuit
- EL18KSLV: Compressor overload -drive module

Split & Multi-Split
5 means different things on different Split & Multi-Split models. Enter your model number to see only your reading, or find your model below.
Models: CBK45UHPT, CBK45UHVT
Air handler (indoor)
Check sensor connections. Ensure connection is clean and tight.
CBK45UHVT
Check for 24VAC power connection to the R terminal inputs on the RDSC. R-inputs must be energized for the RDSC to function.
CBK45UHPT
Check for 24VAC pow- er connection to the R terminal inputs on the RDSC. R-inputs must be energized for the RDSC to function.
R-input not available
R-input not available
R-input not available
R-input not available
R-input not available
R-input not available
HSXB15, XC15, XP15, XP19
1Outdoor unit power disconnect is open. 2Unit circuit breaker or fuse(s) is open. 3Unit contactor has failed to close. (cid:4) Check compressor contactor wiring and connectors (cid:4) Check for compressor contactor failure (burned, pitted or open) (cid:4) Check wiring and connectors between supply and compressor (cid:4) Check for low pilot voltage at compressor contactor coil 4High pressure switch is open and requires manual reset. 5Open circuit in compressor supply wiring or connections. 6Unusually long compressor protector reset time due to extreme ambient tempera- ture. 7Compressor windings are damaged. (cid:4) Check compressor motor winding resistance
HSXB15
1 Outdoor unit power disconnect is open. 2 Unit circuit breaker or fuse(s) is open. 3 Unit contactor has failed to close. 4 High pressure switch is open and requires manual reset. 5 Open circuit in compressor supply wiring or connections. 6 Unusually long compressor protector reset time due to extreme ambient temperature. 7 Compressor windings are damaged.
XC15
1Outdoor unit power disconnect is open. 2Unit circuit breaker or fuse(s) is open. 3Unit contactor has failed to close. 4High pressure switch is open and requires manual reset. 5Open circuit in compressor supply wiring or connections. 6Unusually long compressor protector reset time due to extreme ambi- ent temperature. 7Compressor windings are damaged.
XP15
1Outdoor unit power disconnect is open. 2Unit circuit breaker or fuse(s) is open. 3Unit contactor has failed to close. 4High pressure switch is open and requires manual reset. 5Open circuit in compressor supply wiring or connections. 6Unusually long compressor protector reset time due to extreme ambient temperature. 7Compressor windings are damaged.
Open Circuit
Open Circuit
Open Circuit
Open Circuit
Open Circuit
Models: EL18KSLV
Heat pump (outdoor)
compressor current or input current been detected by compressor drive module software(seconds leve l )
Compressor overload -drive module